Alarm code Description Type
A01 Water temperature alarm Automatic reset
A02 Oil pressure alarm Manual reset
A03 Thermal relay alarm Manual reset
A04 Pressure switch alarm Automatic reset
A05 Low battery level alarm Automatic reset
A06 Damaged room sensor alarm Manual reset
A07 Damaged defrost sensor alarm Warning only
A08 Starting failure/damaged alternator Manual reset
A09 High/low temperature alarm Warning only
A10 Radiator water level alarm Warning only
A11 Oil level alarm Warning only
A12 Air filter alarm Warning only
A13 Oil filter alarm Warning only
A14 Power card not present Automatic reset
A15 Damaged condensing sensor alarm Warning only
A16 Damaged water sensor alarm Warning only
A17 Door switch open alarm Automatic reset
A01 Water temperature alarm
This occurs when the radiator's water temperature exceeds the permitted value.
It turns off the diesel engine until the temperature returns to normal values.
A02 Oil pressure alarm
This alarm occurs if the engine's oil pressure drops; it permanently turns off the
diesel engine. To start the machine again, the alarm must be reset using the pro-
cedure described in the paragraph above and by pressing the ON/OFF key.
A03 Thermal relay alarm
This alarm occurs if abnormal electric motor current input values occur and it
turns off the machine. To reset the alarm, the machine must be de-energized, the
electrical switchboard must be opened, and the thermal relay must be reset by
pressing the blue button. Then close the switchboard and energize the machine
again. Go to the driver's cabin control and press the ON/OFF key.